Nanmac LogoNanmac Logo
ISO 9001:2015/AS 9100 D
ISO/IEC 17025:2017 (CALIBRATION)
PJLA CALIBRATION
(SDVOSB) Service Disabled Vet Owned Small Business
(SDVOSB) Service Disabled Vet Owned Small Business

Contact Us

MADE IN USA

About UsCapabilitiesProductsIndustries ServedCalibrationCertificationsTechnical PapersContact

Temperature and Process Controllers

Proportional • PID • Ramp Soak • Limit

H34 Series

Temperature and Process Controllers

The H34-540 Series is 1/16 DIN or 1/4 DIN temperature controller with auto tuning PID control capabilities. One of four user programmable set points may be selected. For PID control in the form of time proportional relay on/off output, time proportional voltage pulse, or 4-20 mAmp signal control. Its universal input accepts 23 inputs varieties, including thermocouple, RTD, and voltage inputs can be easily configured for a 4-20 mAmp input. The relays may be programmed as alarms with 20 different high, low, and deviation alarm types which can include fail-safe operation. Digital input options add the ability of external contacts to operate the controller. With RS-485 serial communication options include protocols for master/slave set point control, modbus ASCII and RTU.

The H34-550 Series is 1/16 DIN or 1/4 DIN ramp and soak controller with auto-tuning PID control capabilities. Two programs store 15 segments each for precision set point control. At the completion of a program, the controller can hold a set point, stop the outputs, or loop the completion of a program. Thus, enabling one 30 segment program to be used. Its universal ”nput accepts 23 inputs varieties, including hermocouple, RTD, and voltage inputs can easily be configured for a 4-20 mAmp input. The relays may be programmed as alarms with 20 different high, low, and deviation alarm types which include fail-safe operation. Digital input options add the ability of external contacts to operate the controller and digital output options are available. With RS-485 serial communication options include protocols for master/slave set point control, modbus ASCII and RTU.

Temperature and Process Controllers
H34•540 Series Temperature Controllers - Specifications
Part No.DIN SizeDescription
H34-540-6RA-11
H34-540-6RA-14
H34-548-6RB-21
H34-548-6RB-24
H34-549-6RB-24
1/16
1/16
1/4
1/4
1/4
2 Relays 1 Analog Output, 2 Digital Imputs, Heating or Cooling
2 Relays 1 Analog Output, RS-485 Communications, Heating or Cooling
3 Relays 2 Analog Outputs, 2 Digital Imputs, Heating or Cooling
3 Relays 2 Analog Outputs, RS-485 Communications, Heating or Cooling
3 Relays 2 Analog Outputs, RS-485 Communications, Heating or Cooling
H34-SSO Series Ramp Soak Controllers - Specifications
Part No.DIN SizeDescription
H34-550-6RA-14
H34-558-6RA-26
1/16
1/4
2 Relays 1 Analog Output, RS-485 Communications
3 Relays 2 Analog Outputs, & 4 Digital Imputs, RS-485 Communications
H34-570 Seriea Limit (On/Off} Controllers - Specifications
Part No.DIN SizeDescription
H34-570-6RA-10
H34-578-6RA-14
1/16
1/4
2 Latching_Relay 1 Alarm Relay, 1 Analog Output
3 Relays 1 Analog Outputs, & 4 Digital Imputs, RS-485 Communications
Specifications
Input TypeThermocouple TypeTemperature RangeAcccuracy*
ThermocoupleB
C(W5)
E
J
K
L
N
Platinel II

R
S
T
U
32 to 3,300°F (0 to 1,800°C)
32 to 4,200°F (0 to 2,300°C)
-300 to 1,800°F (-199.9 to 999.9°C)
-300 to 2,300°F (-199.9 to 999.9°C)
0 to 2,300°F (-199.9 to 999.9.9°C)
-300 to 1,600°F (-199.9 to 999.9°C)
-300 to 2,400°F (-200 to 1,300°C)

32 to 2,500°F (0 to 1,390°C)
32 to 3,100°F (0 to 1,700°C)
32 to 3,100°F (0 to 1,700°C)
-300 to 750°F (-199.9 to 400.0°C)
-300 to 750°F (-199.9 to 400.0°C)
400°C : +- 0.15% FS +- 1 digit
400°C : +- 5% +- 1 digit
+- 0.2% FS +- 1 digit
0°C : +- 0.1% FS +- 1 digit
0°C : +- 0.2% FS +- 1 digit
0°C : +- 0.1% FS +- 1 digit
0°C : +- 0.25% FS +- 1 digit
+- 0.1% FS +- digit
+- 0.15% FS +- 1digit
RTDJPtA
JPtB
JtA
PtB
PtC
-199.9 to 999.9°F (-199.9 to 500.0°C)
-199.9 to 300.0°F (-150.0 to 150.0°C)
-300.9 to 1,560°F (-199.9 to 850.0°C)
-199.9 to 999.9°F (-199.9 to 500.0°C)
-4.0 to 212.0°F (-19.99 to 99.99C)
+- 0.1% FS +- 1 digit
+- 0.1% FS +- 1 digit
+- 0.2% FS +- 1 digit
Process0.4 to 2.0V
1.000 to 5.000
0 to 10V
-10 to 20mV
0 to 100mV
0.400 to 2.000
1.000 to 5.000
0.00 to 10.00
-10.00 to 20.00
0.0 to 100.0
+- 0.1% FS +- 1 digit
Display range can be scaled between -1999 and 9999.
4 to 20 mA Input
To aocept a 4 to 20 mA slgnal, select 0.4 to 2.0 VDG input and oonnem a 100D reslstar across the input terminals.

*Performance within recommended operating conditions (10 to 50°C, 20 to 90°A RH)

**For a range scale of 0 to 100°C: +0.3°C +1 digit, and for a range scale of -100 to 100°C. +0.5°C +1 digit

ContactIndustries ServedTechnical PapersCapabilitiesTerms & Conditions

© 2024 Nanmac Corporation

Follow us onNanmac LinkedIn Page Link