Flip forwardMIXER TEMPERATURE SENSORS - C8B Series Bookmark this page!
For Non-Sanitary Applications
(click here for Sanitary Applications)

Contact a NANMAC Engineer

Click to Call

NANMAC's Mixer Temperature Sensors are economically designed sensors for use in steam or water-jacketed industrial mixers and blenders.

These mixer temperature sensors use either the NANMAC Right-Angle Ribbon Thermocouple sensor, or a Pt-100 Ohm RTD. Sensors will operate to 400°F continuous maximum service temperature and pressures to 1000 PSI (Higher temperatures and pressure ranges are available - consult factory.)


Series GM Sensor has an overall length of about 2-1/2 inches, it utilizes an exposed flush mounted ribbon Thermocouple sensing element which measures the true mix temperature without protruding into the mix item. Response time is in the low milliseconds. This design eliminates conduction errors caused by gradients in the wall. Available in ANSI Calibration Types J, K, E and T. All units come with 3 feet of leads.

Series GD Sensor also has a length of about 2-1/2 inches and is made with a stainless steel diaphragm on the sensing tip. The diaphragm is only 0.015" thick, thus conduction errors are minimized. This model is available in ANSI Calibration Types J, K, E, and T. It is also available with a 3 wire Pt-100 ohm RTD sensor. This RTD has an Alpha = 0.00385 (DIN - 43760).

Mounting Receptacles (MR) for the NANMAC General Purpose Mixer Thermocouples are available for use in mixers with wall thickness up to 3 inches. These receptacles are fully machined and are ready to be welded into your mixer wall. All Mounting Receptacles come with the appropriate spacer and a gland nut.

After welding the receptacle in place, the end surface protruding into the mixer can be machined or ground off and contoured to match the interior surface of your mixer wall. Copper spacers are then used to align the sensor flush with the inside surface. Receptacles are available in lengths from 1-1/2 to 3 inches in 1/4 increments, see price chart for details.

ORDERING INFORMATION

. When ordering sensors, specify Part No. and Calibration type. Example: C8B-10-J
. When ordering Mount Receptacles (MR) specify Part No. Example: C8B-40
. All sensors come with 36" of lead wire, click here for other termination styles
. All Mounting Receptacles come with a set of 5 copper washers, 1 each in thickness of 0.063", 0.032", 0.016", 0.010", and 0.005" and the appropriate spacer and a gland nut.

©2005 Nanmac Corporation - Framingham, MA USA